Home > Enerpro > SCR Firing Boards > FCRO4100
FCRO4100
Parameter | Unit | Value |
System Phases | – | 1 |
Maximum Mains Voltage | V | 480 |
System Frequency | Hz | 50 or 60 |
Operating Temperature | °C | -5 to 85 |
Converter Topologies | – | Center tap rectifier, AC controller or bridge rectifier (2- and 4-quadrant operation) |
Regulator | – | Two Plug-In boards can be connected depending on the application. The VRCL1P-1 is made for voltage control and has current limiting capability.The PTIR-1 is made for 4-quadrant rectifiers and allows the introduction of dead times between the polarity switching. |
Delay Angle Control Range | ° | 10 to 170 |
Delay Angle Control Signal | – | 0V to 5V; 0.85V to 5V; 0V to 10V; 0mA to 20mA; 4mA to 20mA or custom |
Delay Angle Calculation | – | Analog PLL implemented on proprietary ASIC |
Pulse Profile | – | “Picket fence” profile, high initial current pulse followed by softer pulses to ensure conduction |
Control voltage supply | – | On-board transformer uses mains voltage to power the board |
Others | – | Isolated gate drive circuits; Fully Connectorized; Soft Start and Soft Stop (independently configurable); Power-on Inhibit (avoids sending pulses at turn-on); External Inhibit Signal |